Model :SP24
Dimension :120X120X18mm, 186X140X41mm
Power supply :AC100-240V,50-60Hz
Power consumption :< 3W
Suitable power of pump :1 pump possible to be connected, output power < 300W
Inputs :1 x PT1000 sensor temperature probe =500℃, silicon cable =280?; 2 x NTC10K sensor temperature probe=135℃, PVC cable =105℃
Water proof grade :IP40
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Split pressurized solar water heater CONTROLLER SP24

split pressurized solar water heating system controller SP24

split pressurized solar water heating system controller SP24

split pressurized solar water heating system controller SP24

Suitable for Split pressurized solar water heater system

Main technical data:

1. Dimension: 120X120X18mm, 186X140X41mm
2. Input voltage: 200V~240V AC or 100V~120V AC
3. Power: =3W
4. Accuracy of temperature measuring: <2℃
5. Range of temperature measuring: 0~99℃
6. Input signals:
1 x PT1000 sensor temperature probe =500℃, silicon cable =280℃;
2 x NTC10K sensor temperature probe=135℃, PVC cable =105℃
7. Output signals:
1 x Auxiliary heating output (Max. load current: 12A)
2 x Relay output (Max. load current: 1.5A)
8. Range of environment temperature: -10~50℃
9. Water protection grade: IP40

Main functions:

1.Time display
2.Temperature difference circulation
3.Tank overheating protection
4.High temperature protection of system
5.Frost protection of pipeline and collector
6.Three periods of time adjustable on pipeline circulation
7.Three periods of time adjustable on auxiliary heating
8.Anti-bacteria function
9.Holiday function